UFC760BE143

¥5,240.00

argument
Maximum output current: 1.5A/ phase
Power input: DC 15V to 36V, 2.5A MAX; In some configurations, the input voltage ranges from 48 to 57VDC
Excitation current range: (L excitation)0.3 to 1.5A/ phase, (H excitation)0.15 to 0.75A/ phase
Drive system: Chopper Constant current Pentagonal connection (H/L)
Number of splits: Microsteps: 1 to 100 splits
Input and output signals: CW, CCW input, optical coupler input; Pulse width more than 1μs; L=0 ~ 0.5V, H=4 ~ 5V
specification
Power failure alarm: The alarm can be output through the relay
Communication protocol: Compatible with EtherNet/IP, Profinet, EtherCAT, CC-Link IE and DNP 3.0 and other industrial communication protocols
Compliant with IEEE 802.3at standard, power supply up to 30 watts per port, and backward compatible with IEEE 802.3af standard
Size and weight
Dimensions: Approximately 144.3mm (H) x 26.1mm (W) x 94.9mm (D)
Weight: 390g

Category:

Description

trait
High precision control: multi-degree of freedom and nonlinear control algorithm are used to achieve high dynamic response and high precision current, speed and position control
Multiple configuration options: Support high-precision sine-cosine encoder, rotary transformer speed feedback, resolution up to 24bit per turn
High reliability and durability: The use of high-quality materials and strict production processes to ensure stable operation in a variety of harsh working environments
Fault diagnosis function: Simple and easy to use design and fault diagnosis function, convenient equipment maintenance and troubleshooting
Flexibility and convenience: Support a variety of different configuration options, can be flexibly configured according to the actual application requirements

argument
Maximum output current: 1.5A/ phase
Power input: DC 15V to 36V, 2.5A MAX; In some configurations, the input voltage ranges from 48 to 57VDC
Excitation current range: (L excitation)0.3 to 1.5A/ phase, (H excitation)0.15 to 0.75A/ phase
Drive system: Chopper Constant current Pentagonal connection (H/L)
Number of splits: Microsteps: 1 to 100 splits
Input and output signals: CW, CCW input, optical coupler input; Pulse width more than 1μs; L=0 ~ 0.5V, H=4 ~ 5V
specification
Power failure alarm: The alarm can be output through the relay
Communication protocol: Compatible with EtherNet/IP, Profinet, EtherCAT, CC-Link IE and DNP 3.0 and other industrial communication protocols
Compliant with IEEE 802.3at standard, power supply up to 30 watts per port, and backward compatible with IEEE 802.3af standard
Size and weight
Dimensions: Approximately 144.3mm (H) x 26.1mm (W) x 94.9mm (D)
Weight: 390g

Reviews

There are no reviews yet.

Be the first to review “UFC760BE143”

Your email address will not be published. Required fields are marked *

Post comment