RED615

¥6,252.00

argument
Power supply voltage: up to 80V DC, providing better dynamic drive performance of the motor.
Driving current: bipolar constant current driving mode, the maximum driving current can reach 6.0A per phase.
Communication protocols: Support a variety of communication protocols, such as Modbus, DNP3, IEC 60870-5-103 and IEC61850, and comply with the substation IEC61850 communication standard.
specification
Features: The RED615 provides selective split-phase line differential protection, which can be monitored by sensors or traditional CT or PT. It also has directional overcurrent, non-directional overcurrent, ground protection, voltage, frequency protection and measurement functions.
Configuration: The RED615 has pre-configured standard configurations, including line differential communication, so that it can be combined faster and easier to meet the different application needs of users.

Category:

Description

trait
Versatility: Protection, control, monitoring and management functions integrated in a single relay protection unit provide a compact and versatile solution for public and industrial distribution systems.
Fast response: The panel uses advanced digital technology to monitor the status of the power system in real time and respond quickly to abnormal situations.
Flexible configuration: Supports a variety of standard configurations and optional functions, and can be changed through signal matrix or graphical application functions to meet the application requirements of different users.
Communication capability: Supports multiple communication protocols and includes an optional Ethernet port for ring self-healing communication.

argument
Power supply voltage: up to 80V DC, providing better dynamic drive performance of the motor.
Driving current: bipolar constant current driving mode, the maximum driving current can reach 6.0A per phase.
Communication protocols: Support a variety of communication protocols, such as Modbus, DNP3, IEC 60870-5-103 and IEC61850, and comply with the substation IEC61850 communication standard.
specification
Features: The RED615 provides selective split-phase line differential protection, which can be monitored by sensors or traditional CT or PT. It also has directional overcurrent, non-directional overcurrent, ground protection, voltage, frequency protection and measurement functions.
Configuration: The RED615 has pre-configured standard configurations, including line differential communication, so that it can be combined faster and easier to meet the different application needs of users.

Reviews

There are no reviews yet.

Be the first to review “RED615”