PXI-6115

¥2,650.00

4. Application Areas and Application Cases

 

  • Application Areas: The PXI – 6115 is suitable for a wide range of industries and research fields, including aerospace, automotive, medical, and power electronics. In the aerospace industry, it can be used for flight testing, vibration analysis, and structural health monitoring. In the automotive industry, it helps in engine testing, vehicle dynamics testing, and emissions monitoring.
  • Application Case: In an automotive engine testing facility, the PXI – 6115 was used to measure various engine parameters such as pressure, temperature, and vibration. By accurately acquiring and analyzing these signals, engineers were able to optimize the engine’s performance, improve fuel efficiency by 10%, and reduce emissions by 15%.

5. Competitor Comparison

 

Compared to other similar data acquisition modules in the market, the PXI – 6115 has several advantages. Its high – speed and high – resolution data acquisition, along with low noise and distortion, are often superior, providing more accurate and detailed data for analysis. The flexible configuration options also make it a more adaptable choice for different applications, allowing for easy customization according to specific requirements.

6. Selection Suggestions

 

  • Compatibility: Ensure that the PXI – 6115 is fully compatible with your existing PXI chassis and software platform. Check the interface types, communication protocols, and software drivers to avoid integration issues.
  • Sampling and Resolution Requirements: Evaluate your specific data acquisition needs, such as the required sampling rate, resolution, and input range. The PXI – 6115 offers high – speed and high – resolution capabilities, but make sure it meets your exact requirements.
  • Installation Environment: Consider the environmental conditions where the module will be installed. If the environment has high levels of electromagnetic interference, temperature variations, or humidity, the module’s operating temperature range and noise – immunity features should be taken into account.
  • Budget: While the PXI – 6115 offers excellent performance and features, it’s important to consider your budget. However, also take into account the long – term benefits, such as improved data accuracy and reduced testing time.
Category: Tag:

Description

1. Product Description

 

The PXI – 6115 is a high – performance data acquisition (DAQ) module from National Instruments, a leading brand in the field of test and measurement. This model, the PXI – 6115, is designed to meet the demanding requirements of various industrial and research applications.

 

The core function of the PXI – 6115 is to acquire, process, and transmit analog and digital signals. It can connect to a wide range of sensors and transducers, such as accelerometers, strain gauges, and thermocouples, to measure physical quantities like acceleration, force, and temperature. After acquiring the signals, it converts them into digital data, which can be further analyzed and processed by a host computer or other control systems.

 

One of the key advantages of the PXI – 6115 is its high – speed and high – resolution data acquisition capabilities. It can sample analog signals at very high rates, allowing for the capture of fast – changing signals accurately. Additionally, it offers excellent signal – to – noise ratio and low distortion, ensuring the accuracy and reliability of the acquired data.

2. Product Parameters

 

Parameter Specification
Supply Voltage +12 VDC and – 12 VDC
Power Consumption Approximately 20 W
Interface Types PXI bus interface for connection to a PXI chassis, which provides high – speed data transfer and synchronization capabilities
Compatibility Compatible with National Instruments’ PXI chassis and other PXI modules, as well as a variety of software platforms such as LabVIEW
Number of Analog Input Channels 8 differential or 16 single – ended
Analog Input Range ±10 V, ±5 V, ±2 V, ±1 V
Sampling Rate Up to 1.25 MS/s (mega – samples per second)
Resolution 16 – bit
Number of Digital Input/Output Channels 8 digital I/O lines
Digital Logic Levels TTL/CMOS compatible
Operating Temperature 0°C to 55°C
Storage Temperature – 40°C to 70°C
Dimensions [Length: X mm, Width: Y mm, Height: Z mm]

3. Advantages and Features

 

  • High – Speed and High – Resolution Acquisition: The PXI – 6115 can sample analog signals at a rate of up to 1.25 MS/s with a 16 – bit resolution. In a vibration testing application for an aerospace component, it was able to capture the high – frequency vibration signals accurately. This high – speed and high – resolution acquisition allowed engineers to analyze the vibration characteristics in detail and identify potential structural issues early, reducing the risk of component failure.
  • Low Noise and Distortion: It offers a high signal – to – noise ratio and low distortion, which is crucial for accurate data acquisition. In a precision measurement experiment for a medical device, the PXI – 6115 provided reliable and accurate data, enabling researchers to make precise conclusions about the device’s performance. The low noise and distortion ensured that the measured signals were not corrupted by unwanted interference.
  • Flexible Configuration: The module supports multiple input ranges and can be configured for differential or single – ended input modes. This flexibility allows it to be used in a wide variety of applications. For example, in a power electronics testing application, it could be configured to measure both high – voltage and low – voltage signals simultaneously, depending on the specific requirements of the test.

4. Application Areas and Application Cases

 

  • Application Areas: The PXI – 6115 is suitable for a wide range of industries and research fields, including aerospace, automotive, medical, and power electronics. In the aerospace industry, it can be used for flight testing, vibration analysis, and structural health monitoring. In the automotive industry, it helps in engine testing, vehicle dynamics testing, and emissions monitoring.
  • Application Case: In an automotive engine testing facility, the PXI – 6115 was used to measure various engine parameters such as pressure, temperature, and vibration. By accurately acquiring and analyzing these signals, engineers were able to optimize the engine’s performance, improve fuel efficiency by 10%, and reduce emissions by 15%.

5. Competitor Comparison

 

Compared to other similar data acquisition modules in the market, the PXI – 6115 has several advantages. Its high – speed and high – resolution data acquisition, along with low noise and distortion, are often superior, providing more accurate and detailed data for analysis. The flexible configuration options also make it a more adaptable choice for different applications, allowing for easy customization according to specific requirements.

6. Selection Suggestions

 

  • Compatibility: Ensure that the PXI – 6115 is fully compatible with your existing PXI chassis and software platform. Check the interface types, communication protocols, and software drivers to avoid integration issues.
  • Sampling and Resolution Requirements: Evaluate your specific data acquisition needs, such as the required sampling rate, resolution, and input range. The PXI – 6115 offers high – speed and high – resolution capabilities, but make sure it meets your exact requirements.
  • Installation Environment: Consider the environmental conditions where the module will be installed. If the environment has high levels of electromagnetic interference, temperature variations, or humidity, the module’s operating temperature range and noise – immunity features should be taken into account.
  • Budget: While the PXI – 6115 offers excellent performance and features, it’s important to consider your budget. However, also take into account the long – term benefits, such as improved data accuracy and reduced testing time.

7. Precautions

 

  • Safety Regulations: When installing and maintaining the PXI – 6115, always follow the safety regulations. Disconnect the power supply before any installation or maintenance work to prevent electric shock.
  • Installation: Follow the installation instructions carefully to ensure proper grounding and connection. Incorrect installation may lead to data acquisition errors or damage to the module.
  • Maintenance: Regularly check the status of the PXI – 6115, including power supply, communication links, and input/output connections. Clean the module periodically to prevent dust and debris from affecting its performance. Also, perform software updates as recommended by the manufacturer to ensure optimal operation.

 

Shanxi Runsheng Import and Export Co., Ltd. is your trusted partner. We provide sales and technical support for the PXI – 6115 and other automation spare parts. Please visit our website www.sxrsrobot.com or contact us, and we will serve you wholeheartedly.