PXI-6052E

¥2,124.00

2. Applications

 

  • Data Acquisition in Research: In scientific research, the PXI – 6052E is widely used for data acquisition. For example, in a physics experiment, it can measure electrical signals from sensors detecting physical phenomena such as temperature, pressure, and magnetic fields. In a biology research project, it can record physiological signals like heart rate and brainwaves.
  • Automotive Testing: In the automotive industry, it is used for vehicle component testing. It can measure the performance of engines, transmissions, and electrical systems by collecting data from sensors placed on these components. For instance, it can monitor the voltage and current of the battery, the temperature of the engine, and the pressure in the fuel system.
  • Industrial Process Monitoring: In manufacturing plants, the PXI – 6052E can monitor industrial processes. It can measure parameters like the temperature, pressure, and flow rate of fluids in a chemical manufacturing process, ensuring the process runs smoothly and within the specified parameters.

3. Weight and Dimensions

 

  • Weight: The PXI – 6052E weighs approximately 0.2 kg. Its lightweight design makes it easy to install and handle within a PXI chassis, which may house multiple modules.
  • Dimensions: It follows the standard PXI form – factor. The dimensions are typically 100 mm in width, 160 mm in height, and 160 mm in depth. This compact size allows it to be integrated into a PXI system without taking up excessive space.
Category: Tag:

Description

1. Parameter Specifications

 

  • Power Supply: The PXI – 6052E typically operates with a 5V DC power supply provided by the PXI chassis. It has a low power consumption, around 10 – 15W, which is energy – efficient for long – term operation in a test and measurement environment.
  • Analog Inputs: It offers 16 single – ended or 8 differential analog inputs. The input voltage range can be configured from ±10V to ±0.1V, providing flexibility for measuring various analog signals. The analog – to – digital converter (ADC) has a 12 – bit resolution and can sample at rates up to 200 kS/s (kilo – samples per second), enabling accurate and fast data acquisition.
  • Analog Outputs: There are 2 analog outputs with a 12 – bit resolution and an update rate of up to 1 MS/s (mega – samples per second). The output voltage range is usually ±10V, suitable for driving analog – controlled devices.
  • Digital I/O: It features 32 TTL – compatible digital I/O lines. These can be used for general – purpose digital control, such as triggering external devices or receiving status signals.
  • Counter/Timers: The module includes 3 24 – bit counter/timers. They can be used for tasks like frequency measurement, pulse generation, and time – based control.

2. Applications

 

  • Data Acquisition in Research: In scientific research, the PXI – 6052E is widely used for data acquisition. For example, in a physics experiment, it can measure electrical signals from sensors detecting physical phenomena such as temperature, pressure, and magnetic fields. In a biology research project, it can record physiological signals like heart rate and brainwaves.
  • Automotive Testing: In the automotive industry, it is used for vehicle component testing. It can measure the performance of engines, transmissions, and electrical systems by collecting data from sensors placed on these components. For instance, it can monitor the voltage and current of the battery, the temperature of the engine, and the pressure in the fuel system.
  • Industrial Process Monitoring: In manufacturing plants, the PXI – 6052E can monitor industrial processes. It can measure parameters like the temperature, pressure, and flow rate of fluids in a chemical manufacturing process, ensuring the process runs smoothly and within the specified parameters.

3. Weight and Dimensions

 

  • Weight: The PXI – 6052E weighs approximately 0.2 kg. Its lightweight design makes it easy to install and handle within a PXI chassis, which may house multiple modules.
  • Dimensions: It follows the standard PXI form – factor. The dimensions are typically 100 mm in width, 160 mm in height, and 160 mm in depth. This compact size allows it to be integrated into a PXI system without taking up excessive space.

4. Features

 

  • High – Speed and High – Precision: With its 12 – bit ADC and high sampling rate, the PXI – 6052E can accurately capture and digitize analog signals in real – time. This is crucial for applications that require fast and precise data acquisition, such as high – frequency signal analysis.
  • Flexible Configuration: The ability to configure input and output ranges, as well as the digital I/O and counter/timer functions, provides great flexibility for different application requirements. Users can customize the module according to their specific needs.
  • PXI Compatibility: As a PXI module, it is fully compatible with the PXI platform. This allows for easy integration with other PXI modules and chassis, enabling the construction of complex test and measurement systems.

5. Stability and Reliability

 

  • Robust Construction: The module is built with high – quality components and a durable housing. It can withstand the rigors of industrial and laboratory use, including temperature variations, humidity, and mechanical vibrations.
  • Error – Handling and Calibration: It has built – in error – handling mechanisms and calibration features. These ensure accurate measurements over time and can detect and correct errors during data acquisition, enhancing the reliability of the system.
  • Quality Manufacturing: The manufacturing process adheres to strict quality standards. This guarantees long – term stable performance and reduces the risk of component failures.

6. Real – World Examples

 

  • Semiconductor Testing: In a semiconductor manufacturing facility, the PXI – 6052E is used to test the electrical characteristics of integrated circuits. It can measure parameters such as voltage, current, and resistance, ensuring the quality of the semiconductors before they are shipped to customers. By accurately capturing the electrical signals, it helps to identify any defects or performance issues in the integrated circuits.
  • Aerospace Component Testing: In the aerospace industry, the PXI – 6052E is used to test the performance of aircraft components. For example, it can measure the vibration and temperature of engine components during simulated flight conditions. This data is crucial for ensuring the safety and reliability of the aircraft. The module’s high – speed data acquisition and accurate measurement capabilities allow engineers to analyze the behavior of the components under different conditions and make necessary improvements.