ProSoft PLX82-EIP-PNC

¥16,452.00

The ProSoft PLX82 – EIP – PNC is a communication gateway that connects Ethernet/IP – based controllers with PROFINET RT devices. It allows for secure, high – speed communications between two major industrial automation protocols3.

Category:

Description

Product Description

The ProSoft PLX82 – EIP – PNC is a communication gateway that connects Ethernet/IP – based controllers with PROFINET RT devices. It allows for secure, high – speed communications between two major industrial automation protocols3. This gateway enables Ethernet/IP controllers to control up to 36 PROFINET RT devices, including field I/O, drives, HMIs, and controllers34. It is a stand – alone DIN – rail mounted unit with two Ethernet ports for communication, remote configuration, and diagnostics34. The onboard SD card slot is used for storing configuration files34.

Product Parameters

  • Power Supply: 24 VDC nominal, 10 – 36 VDC allowed.
  • Current Load: 24 VDC nominal @ 400mA, 10 – 36 VDC @ 610 mA maximum.
  • Ethernet Port: 10/100 Mbit RJ45 connector with electrical isolation of 1500 Vrms at 50 – 60 Hz for 60 seconds.
  • Supported PLC Types: PLC 2, PLC 5, SLC, CLX, CMPLX3.
  • Class 3 Server Connections: 53.
  • Class 3 Client Connections: Connected: 2, Unconnected: 13.
  • Class 1 I/O Connections: 83.
  • Max I/O Connection Size In/Out: 248/2483.
  • Min RPI Time: 2 ms (1 connection), 8 ms (8 connections)3.

Advantages and Features

  • High – Speed Control: It offers multiple I/O connections, enabling high – speed control for large PROFINET I/O systems3. For example, in a complex manufacturing assembly line with numerous PROFINET – connected devices, the PLX82 – EIP – PNC can ensure quick and accurate data transfer and control, improving production efficiency.
  • Isolated Ethernet Ports: The isolated Ethernet ports allow devices on different protocols to be on different subnets, enhancing network flexibility and security3. This feature is beneficial in industrial settings where multiple types of devices with different communication requirements need to be integrated into a single network.
  • Certified and Tested: It is ODVA – approved and has PROFINET V2 certification with PROFINET Class A compliance. It has also been field – tested with multiple PROFINET devices from various vendors, ensuring its reliability and compatibility in real – world applications3.

Application Areas and Application Cases

  • Applicable Industries and Scenarios: The PLX82 – EIP – PNC is suitable for a variety of industries, including manufacturing, energy, and automation control. In manufacturing, it can be used to connect different automation devices on the production line to a unified control system. In the energy sector, it can be applied to monitor and control power generation equipment and distribution systems. In automation control, it helps integrate various field devices and controllers to achieve efficient and reliable automation operations.
  • Application Case: In a large – scale manufacturing plant, there were multiple PROFINET – based robotic arms and conveyor belts that needed to be integrated with an Ethernet/IP – based central control system. The ProSoft PLX82 – EIP – PNC was used as a gateway. It successfully established a high – speed and stable communication link, allowing the central control system to precisely control the movement and operation of each robotic arm and conveyor belt. As a result, the production process was highly automated, reducing errors and increasing production capacity.

Comparison with Similar Products

Compared to other similar products, the PLX82 – EIP – PNC has several advantages. It has a relatively high number of supported PROFINET devices (up to 36), which is beneficial for large – scale industrial automation systems. Its ODVA approval and PROFINET V2 certification with Class A compliance ensure its high – quality performance and compatibility with a wide range of devices. The isolated Ethernet ports and multiple I/O connections also provide more flexibility and better performance in complex network environments.

Selection Suggestions

  • Compatibility: Ensure that your existing Ethernet/IP – based controllers and the PROFINET devices you plan to connect are compatible with the PLX82 – EIP – PNC. Check the supported PLC types and device profiles to avoid any compatibility issues.
  • Installation Environment: Consider the installation location. The device has an operating temperature range of 0 ° to 50 °C and a relative humidity of 5% to 95% RH with no condensation. Make sure the installation environment meets these requirements to ensure the normal operation of the gateway.
  • Budget: The cost of the PLX82 – EIP – PNC should be within your budget. However, also consider its long – term benefits, such as improved system performance and reliability, when evaluating the cost – effectiveness.

Precautions

  • Safety Specifications: When installing and using the PLX82 – EIP – PNC, follow the relevant safety regulations. Ensure proper grounding to prevent electrical shock and short circuits.
  • Maintenance Recommendations: Regularly check the status of the device, including the LED indicators, to monitor its operation. Backup the configuration files regularly to the SD card to prevent data loss in case of device failure. Keep the device clean and free from dust and debris to ensure good heat dissipation.

 

Shanxi Runsheng Import and Export Co., Ltd. is your reliable partner. We provide the sales and technical support of ProSoft PLX82 – EIP – PNC and other automation spare parts. Please visit our website www.sxrsrobot.com or contact us, and we will be happy to serve you.