PM803F

¥2,205.00

  • Power Distribution Systems: In industrial and commercial buildings, the PM803F is used to monitor the electrical parameters of power distribution systems. It can measure the voltage, current, and power consumption of different circuits, helping to manage energy usage, detect faults, and ensure the stable operation of the power supply.
  • Renewable Energy Systems: In solar and wind power plants, the PM803F is used to monitor the power generation and grid – connected performance. It can measure the output power, voltage, and frequency of the renewable energy sources, and also monitor the power flow between the renewable energy system and the grid.
  • Industrial Automation: In manufacturing plants, the PM803F is used to monitor the electrical parameters of motors, generators, and other electrical equipment. By monitoring the power consumption and performance of these devices, it can help to optimize the production process, reduce energy waste, and prevent equipment failures.

3. Weight and Dimensions

 

  • Weight: The PM803F weighs approximately 1.2 kg. Its relatively light weight makes it easy to install and handle during the setup and maintenance processes.
  • Dimensions: It has compact dimensions, typically around 200 mm in length, 150 mm in width, and 80 mm in height. These dimensions allow it to be easily installed in standard control cabinets or on DIN rails in industrial environments.

4. Features

 

  • Comprehensive Measurement: The PM803F can measure a wide range of electrical parameters, providing a comprehensive view of the electrical system’s performance.
  • High – Accuracy Measurement: With its high – accuracy measurement capabilities, it can provide reliable data for energy management, power quality analysis, and equipment monitoring.
  • Flexible Communication: The support for multiple communication protocols allows for easy integration with different types of control systems and data acquisition devices, enabling seamless data exchange.
  • User – Friendly Interface: It usually comes with a user – friendly interface, such as a back – lit LCD display, which allows operators to easily view and configure the measured parameters.
Category: Tag:

Description

1. Parameter Specifications

 

  • Power Supply: The PM803F typically operates on a 24V DC power supply. It has a relatively low power consumption, around 10 – 15W, which is energy – efficient for continuous operation in industrial settings.
  • Measurement Ranges:
    • Voltage: It can measure AC and DC voltages in a wide range, such as 0 – 690V AC and 0 – 1000V DC.
    • Current: Capable of measuring currents from a few milliamperes up to several thousand amperes with the use of appropriate current transformers.
    • Power: It can accurately measure active, reactive, and apparent power.
    • Frequency: The frequency measurement range is usually from 45Hz to 65Hz, suitable for most power systems.
  • Accuracy: It offers high – accuracy measurement, with a typical accuracy of ±0.2% for voltage and current measurements, and ±0.5% for power measurements.
  • Communication Interfaces: It supports multiple communication protocols, including Modbus RTU over RS – 485, Profibus DP, and Ethernet TCP/IP. This allows for easy integration with various control systems and data acquisition devices.

2. Applications

 

  • Power Distribution Systems: In industrial and commercial buildings, the PM803F is used to monitor the electrical parameters of power distribution systems. It can measure the voltage, current, and power consumption of different circuits, helping to manage energy usage, detect faults, and ensure the stable operation of the power supply.
  • Renewable Energy Systems: In solar and wind power plants, the PM803F is used to monitor the power generation and grid – connected performance. It can measure the output power, voltage, and frequency of the renewable energy sources, and also monitor the power flow between the renewable energy system and the grid.
  • Industrial Automation: In manufacturing plants, the PM803F is used to monitor the electrical parameters of motors, generators, and other electrical equipment. By monitoring the power consumption and performance of these devices, it can help to optimize the production process, reduce energy waste, and prevent equipment failures.

3. Weight and Dimensions

 

  • Weight: The PM803F weighs approximately 1.2 kg. Its relatively light weight makes it easy to install and handle during the setup and maintenance processes.
  • Dimensions: It has compact dimensions, typically around 200 mm in length, 150 mm in width, and 80 mm in height. These dimensions allow it to be easily installed in standard control cabinets or on DIN rails in industrial environments.

4. Features

 

  • Comprehensive Measurement: The PM803F can measure a wide range of electrical parameters, providing a comprehensive view of the electrical system’s performance.
  • High – Accuracy Measurement: With its high – accuracy measurement capabilities, it can provide reliable data for energy management, power quality analysis, and equipment monitoring.
  • Flexible Communication: The support for multiple communication protocols allows for easy integration with different types of control systems and data acquisition devices, enabling seamless data exchange.
  • User – Friendly Interface: It usually comes with a user – friendly interface, such as a back – lit LCD display, which allows operators to easily view and configure the measured parameters.

5. Stability and Reliability

 

  • Robust Construction: The PM803F is built with a durable housing that can withstand harsh industrial environments, including dust, moisture, and mechanical vibrations.
  • Electrical Protection: It is equipped with over – voltage, over – current, and short – circuit protection mechanisms. These protections help to prevent damage to the device from electrical faults, ensuring its long – term stability and reliability.
  • Quality Components: The use of high – quality electronic components in the manufacturing process contributes to the overall reliability of the PM803F. These components are selected for their performance and durability.

6. Real – World Examples

 

  • Office Building Energy Management: In a large office building, the PM803F is installed in the main power distribution panel. It monitors the voltage, current, and power consumption of different floors and departments. By analyzing the energy consumption data collected by the PM803F, the building management can identify areas of high energy consumption and implement energy – saving measures, such as adjusting the lighting and HVAC systems. This has resulted in a significant reduction in the building’s overall energy consumption and cost.
  • Solar Power Plant Monitoring: In a solar power plant, the PM803F is used to monitor the output power of each solar panel array. It measures the voltage, current, and power generation of the arrays in real – time. If there is a decrease in power generation in a particular array, the PM803F can detect it immediately and send an alarm to the control center. This allows the maintenance team to quickly identify and fix the problem, ensuring the maximum power generation of the solar power plant.