Showing 9733–9744 of 14780 results

REXROTH DKC-11.3-040-7-FW

¥4,509.00
Parameters and specifications:
Function: servo drives, also known as “servo controllers” or “servo amplifiers”, are used to control servo motors.
Applications: Widely used in high-precision positioning systems, especially in industrial robots and CNC machining centers and other automation equipment.
Control mode: There are generally three control modes, including position control mode, torque control mode and speed control mode.
Control algorithm: current, speed, position 3 closed-loop control algorithm based on vector control.

B&R 8LSA25R0060D200-0

¥3,659.00
Parameters and specifications:
Rated voltage: 380V.
Rated power: 60W.
Rated speed: 3,000 rpm (but note that another search result mentions that the nominal speed may be 6,000 rpm, which may be related to the specific model or version).
Number of poles: 4.
Technical description: The motor uses advanced synchronous motor technology to provide excellent dynamic performance and high-precision position control. Its low noise and high performance characteristics also make it widely used in many application fields.

ABB 3BHT300032R1

¥4,526.00

Parameters and Specifications:

  • Input Voltage: 24 V DC ± 20%1
  • Input Current: Max 5 mA / Max 0.5 A1
  • Number of Channels (Input/Output): 16 each12
  • Resolution: 12-bit12
  • Output Type: Relay1
  • Output Range: 4 – 20 mA12
  • Operating Voltage: 220VAC3
  • Operating Temperature: -10…60℃3
  • Relative Humidity: <90%3

JOHNSON MS-NAE5510-1

¥5,416.00
Parameters and specifications:
Input voltage: 24V DC±10%.
Operating temperature: -10℃~ +50℃.
Storage temperature: -20℃~ +70℃.
Humidity: 10%-90%RH (non-condensing).
Processor: ARM Cortex-M4 core.
Memory: 512KB Flash, 96KB RAM.
Digital input: 8 channels, 24V DC.
Digital output: 8 channels, 24V DC, 0.5A per channel.
Analog input: 4 channels, 0-10V DC.
Analog output: 4 channels, 0-10V DC, 12-bit resolution.
Communication: Ethernet, Modbus, TCP, RS485.

EMERSON A6110

¥5,412.00
Parameters and specifications:
Features: Dual channel shaft relative vibration monitor designed to provide extremely high reliability for the plant’s most critical rotating machinery.
Applications: steam, gas, compressors and hydraulic turbomachinery.
Measurement mode: Support hot configuration, zero to peak, peak to peak and other modes.
Input:
Number of inputs: two, independent or combined monitoring modes.
Input type: Eddy current, differential.
Sensor input part number: 6422, 6423, 6424, 6425.
Input resistance: >100 kΩ.
Input voltage range: 0 to -22 VDC.
Input frequency range: lower cutoff frequency 1 or 5 Hz, upper cutoff frequency 50-2000 Hz adjustable.
Specifications:
Dual channel, 3U size, 1 socket plug.
The plug-in module reduces cabinet space requirements by half compared to a traditional four-channel 6U card.
API 670 compliant, hot-swappable modules.
Limit doubling and tripping bypass can be selected remotely.
Front and rear buffering and proportional output, 0/4-20 mA output, 0-10 V output.

Woodward 8440-1849 D

¥6,201.00
Parameters and specifications:
Features: This is a high quality, high stability product for all types of power stations.
Use: Monitor power station operation efficiently and stably.
Series:
8440 Series: Woodward 8440-1849 D is part of Woodward’s 8440 series.
Features:
High quality and high stability: The product is described as a high quality and high stability power plant manager.
Power station monitoring: can efficiently and stably monitor power station operation.

GE HE693THM809C

¥3,052.00
Parameters and specifications:
Brand: GE General Electric.
Category: Thermocouple input module.
Power: Rated.
Applicable industries: including mining, shipping, machinery, transportation, chemical industry, etc.
Application: Ships.
Current: 0-60.
Power consumption: 10V

FOXBORO FBM233

¥6,245.00
Parameters and specifications:
Input signal: Support DC voltage, 4-20 mA current, thermocouple, RTD (thermal resistance), resistance and frequency and other signals.
Output signal: DC voltage, 4-20 mA current and other signals.
Power supply: 12-30 VDC.
Operating temperature: -40 to 85 degrees Celsius.
Field Device Interface: Supports various types of field I/O device protocols, including HART, FOUNDATION Fieldbus, Modbus, and more.
Ethernet interface: 10/100Mbps copper Ethernet.

ABB PHARPS32200000

¥6,032.00
Parameters and specifications:
Input voltage: 90-264VAC.
Input current: 11.5A.
Output voltage: 24VDC.
Output current: 32A.
Power: 768W.
Operating temperature: -20℃~+70℃.
Output voltage accuracy: ±0.5% to ensure the stable operation of DCS system.
Efficiency: up to 90%, reducing energy consumption and heat production.

EMERSON KJ2003X1-BB1

¥5,412.00
Parameters and specifications:
Voltage: 24V.
Current: 100-400A.
Vector graphics Support: Supported.
Display type: IPS.
Size and weight:
Weight: 2KG.
Series:
The KJ2003X1-BB1 is a specific model for EMERSON, not a family name.

ICS TRIPLEX T8110B

¥6,203.00
Parameters and specifications:
Product type: Trusted TMR processor.
Voltage range: 20 to 32V DC.
Heat dissipation: 80 watts.
Used with the chassis: T8100.
Maximum load: 80 watts.
Processor clock: 100 MHz.
I/O interface: Triple redundant intermodule bus.
SOE buffer size: 1000 events, move to CI buffer of 4000 events.
Operating temperature: 0 ° C to 60 ° C (32 ° F to 140 ° F)
Non-operating temperature: -25 ° C to 70 ° C (-13 ° F to 158 ° F).
Supported operating systems: Microsoft Windows XP Professional with Service Pack 1 or 2, Microsoft Windows 2000 Professional with Service Pack 1, 2, or 3, Microsoft Windows Server 2003.
Memory requirements: Minimum 128 megabytes of memory, 256 megabytes of memory recommended.
Processor: The microprocessor produced by Intel Corporation of the United States, the Chinese translation is Pentium I, minimum 450 MHz, Pentium II 733 MHz (or better) is recommended.

GE SR750-P1-G1-S1-HI-A20-R-E

¥5,622.00
Parameters and specifications:
Series: May belong to the 750/760 feeder management relay in the GE Multilin series.
Power supply: 88-300 volts DC.
Frequency: 48-62 Hz.
Analog outputs: Eight 4-20 mah analog outputs.
Protection function: When the current, voltage and other parameters in the power system exceed the set value, the relay protection device will quickly act to cut off the fault circuit or issue an alarm, so as to protect the safety of the equipment and system.