Showing 349–360 of 14780 results

FEM100

¥3,052.00

‌ Specifications and parameters ‌ :

The FEM100 is a fieldbus extension module from Foxboro designed to increase the number of 200 series (or equivalent) FBMS supported by the FCP270 module
Supports 2 Mbps HDLC module fieldbus for communication between FCP270 and 200 series FBMS
Can be installed in a DIN rail mounted modular two – or four-slot expansion baseboard, providing four expansion fieldbuses

‌ function ‌ :

The FEM100 module is mainly used in process control and monitoring systems, especially in the field of industrial automation, such as chemical plants, the petroleum industry, electrical control systems, etc

SCXI-1104C

¥3,625.00

‌ Specifications and parameters ‌ :

‌ Model ‌ : SCXI-1104C
‌ brand ‌ : NI (National Instruments)
‌ Number of channels ‌ : Usually has multiple channels, which may vary from version to version, such as 32 differential analog input channels
‌ resolution ‌ : high precision data acquisition, such as 24-bit analog-to-digital converters, some information indicates 12-bit 3, depending on the product model and configuration.
‌ sampling rate ‌ : The maximum sampling rate is 100 kS/s, but the specific rate may vary according to application requirements
‌ Input voltage range ‌ : ±10 V, suitable for many common signal types and voltage standards
‌ communication protocol ‌ : Supports communication protocols such as Ethernet and IP

 

5X00301G01

¥3,528.00

‌ Specifications and parameters ‌ :

‌ model ‌ : 5X00301G01, usually belongs to analog expansion module or basic bus module, depending on the application scenario.
‌ measuring range ‌ : Support a variety of measuring ranges, such as 0 ~ 16, 20, 25, 30, 35, 45, 60, 80, 100, 120, 150MPa, etc., suitable for different pressure measurement requirements.
‌ accuracy ‌ : high precision, such as ±0.1%, ±0.25%, ±0.5%FS, to ensure the measurement accuracy.
‌ working voltage ‌ : Usually 5 ~ 15V DC, it is also mentioned that the working voltage is 380V or 24V, the specific need to be confirmed according to the actual product model.
‌ output ‌ : analog output, such as 1.5~1.8mv/v, suitable for connection with PLC and other control systems.

8V1090.001-2

¥3,659.00

‌ Specifications and parameters ‌ :

‌ Model ‌ : 8V10901.001-2
‌ brand ‌ : B&R
‌ Supply voltage range ‌ : 400 to 480 VAC
‌ Maximum output frequency ‌ : 600 Hz
‌ Dustproof and waterproof rating ‌ : IP20
‌ Maximum current ‌ : 24 A
‌ weight ‌ : about 4.4 kg
‌ Operating temperature ‌ : up to 55 degrees Celsius
‌ protection ‌ : has overload protection

BENTLY 190065A-00-00-01-01-00

¥3,695.00

‌ Specifications and parameters ‌ :

Model: BENTLY 1900/65A-00-00-01-000
Input type: Support accelerometer, speed sensor or proximity sensor and other types of sensor input
Temperature input: Support E, J, K and T thermocouples and 2 – or 3-wire RTDS
Output: Provides six relay outputs, four 4-20mA logger outputs, and a dedicated buffer output
Communication interface: Support Modbus communication protocol, can communicate with other systems through Ethernet or RS232/485 serial port

3BSE018172R1

¥3,652.00

‌ Specifications and parameters ‌ :

‌ Measuring method ‌ : using RF capacitor, using 16-bit MCU to correct the nonlinearity between frequency and capacitance
‌ Power supply ‌ : 24V DC±10%
‌ output ‌ : Support 4 ~ 20mA three-wire output, and HART protocol (two restrictions)
‌ Measuring medium ‌ : relative permittivity ε>1.6
‌ accuracy ‌ : 0.5%FS
‌ Electrical interface ‌ : M20×1.5
‌ Protection grade ‌ : IP65, suitable for damp, corrosion and other harsh environment
‌ explosion-proof grade ‌ : dⅡBT4
‌ shell material ‌ : aluminum alloy flameproof type
‌ Ambient temperature ‌ : -30 to 70 ° C is supported

JZNC-XRK01D-1

¥3,526.00

‌ Specifications and parameters ‌ :

‌ brand ‌ : YASKAWA.
‌ Input voltage ‌ : 200 to 230 VAC
‌ Output voltage ‌ : 200 to 230 VAC
‌ Rated capacity ‌ : 1 kVA
‌ control mode ‌ : V/f control, open loop vector control, closed loop vector control
‌ Frequency setting range ‌ : 0.01 to 600 Hz
‌ overload capacity ‌ : 150% rated current for 60 seconds, 200% rated current for 3 seconds
‌ Dimensions ‌ : 130 x 260 x 240 mm.
‌ weight ‌ : 7.5 kg

PCI-6123

¥3,526.00

‌ Specifications and parameters ‌ :

‌ Measuring range ‌ : 1ug~100mg
‌ titration rate ‌ : 2.1mg/min
‌ Sensitivity ‌ : 0.1ug~100g is not more than 2%, more than 1mg converted to 0
‌ voltage ‌ : 24V is usually mentioned, but some information indicates that the supply voltage may be 220V or 240V
‌ Maximum output current ‌ : 15A
‌ Operating temperature range ‌ : -25~70℃

MVME162-220

¥3,562.00

‌ Specifications and parameters ‌ :

‌ display ‌ : 17″ SXGA TFT LCD, resolution is 1280×1024, brightness is 300cd/m2, contrast is 500:1, supporting dual display
‌ processor ‌ : May be equipped with an Intel Pentium/Celeron M low-power processor, or MC68LC040/MC68040 microprocessor
‌ memory ‌ : Supports 1 GB of DDR memory. Some configurations may provide 256 MB or 512 MB of memory
‌ storage ‌ : Supports Type II CF cards, DOM, and 2.5″ laptop hard drives
‌ port ‌ : six USB2.0 ports, four serial ports, one parallel port, optional dual network ports, and one PCI expansion slot
‌ other ‌ : Industrial eight-wire resistive touch screen, resolution 4096 x 4096, support Windows 98/NT/2000/XP, Linux, embedded Windows XP and other operating systems

XVME-655

¥3,652.00

‌ Specifications and dimensions ‌ :

‌ specification ‌ : XYCOM XVME-655 specifications may vary slightly depending on the product model and configuration, but the general specification mentioned is 263337
‌ Size ‌ : net depth/length of the product is 135mm

‌ parameter ‌ :

‌ working voltage ‌ : Some information mentions that the working voltage is 1V, but this value is unusually low compared with the common working voltage of industrial equipment, which may be a specific configuration or description error. Generally speaking, the operating voltage of this type of equipment will be higher, such as 220V
‌ Output frequency ‌ : The output frequency is 1kHz

FBM242

¥3,650.00

Product parameters:

Input signal type: The FBM242 can accept various input signal types, such as analog signals, digital signals, etc.
Output signal type: Output signal type of the device, such as 4-20mA, 0-10V, and so on.
Power requirements: Power voltage and current required by the FBM242.
Operating temperature range: The temperature range that the device can withstand under normal working conditions.
Storage temperature range: The temperature range that the device can withstand when it is stored or not working.
Communication interface: Whether the device supports communication interfaces, such as RS-232, RS-485, etc., and describe its communication protocol.

AAI143-H50

¥3,526.00

Product parameters and specifications:

Manufacturer: YOKOGAWA
Model: AAI143-H50
Type: Analog input module
Number of channels: Depending on the specific configuration, multiple analog input channels are usually provided.
Input range: Depending on the model and configuration, support different analog signal input range, such as -10V to +10V, -5V to +5V, 0V to +10V, etc.
Resolution: Represents the smallest voltage change that the module can recognize, usually in millivolts (mV).
Sampling rate: The number of times per second that a module can sample, usually in Hertz (Hz).