NI SCXI-1163R

¥24,158.00

The NI SCXI – 1163R is a relay switch module designed by National Instruments. It features 32 form A (normally open), optically isolated solid – state relays, which are organized in eight banks of four with a single common pole for every bank

Category:

Description

Product Description

The NI SCXI – 1163R is a relay switch module designed by National Instruments. It features 32 form A (normally open), optically isolated solid – state relays, which are organized in eight banks of four with a single common pole for every bank1. This module is mainly used to switch high – voltage loads, with a maximum switching capacity of 200 ma at 240 vac / vdc1. It can be widely used in various industrial and laboratory applications to switch different types of ac and dc voltage and power signals for controlling field instruments1. One of the significant advantages of the NI SCXI – 1163R is its compatibility with multiple software, including LabVIEW, LabWindows, NI – DAQ, and register – level programming software. This allows users to choose the most suitable programming method according to their needs, which can greatly reduce the development time for data acquisition and control applications1.

Product Parameters

  • Relay Type: Form A, solid – state
  • Number of Relays: 32
  • Maximum Switching Voltage: 240 vac / 240 vdc
  • Maximum Switching Capacity: 200 ma
  • Maximum Working Voltage: 450 v
  • Maximum Leakage Current: 1 μA
  • I / O Connector: 48 – pin DIN C male
  • Operating Temperature Range: 0 to 50 °C
  • Dimensions: 6.8 x 8.0 x 1.2 in
  • Weight: 625 g

Advantages and Characteristics

  • High Reliability: The NI SCXI – 1163R uses solid – state relays without moving parts, which have a longer service life and higher reliability than electromechanical relays. For example, in a long – term industrial production environment, the failure rate of this module is extremely low, which can ensure the stable operation of the equipment1.
  • Easy to Integrate: It can be easily integrated with other National Instruments products, such as the SCXI – 1326 terminal block, PXI – 4021 switch controller, and PCI – 4021 switch controller. In an automated production line, it can quickly form a complete control system with other devices, improving the overall production efficiency1.
  • Optical Isolation: The module has optical isolation, which can effectively prevent electrical interference and improve the anti – interference ability of the system. In a complex electromagnetic environment, it can still accurately switch signals and ensure the stability of the control system.

Application Areas and Application Cases

  • Application Areas: The NI SCXI – 1163R is suitable for a variety of industries and scenarios, including manufacturing, energy, laboratory testing, and automation control. In the manufacturing industry, it can be used to control the on – off of various production equipment; in the energy industry, it can be used to switch high – voltage power signals; in laboratory testing, it can be used to control the power supply of experimental equipment.
  • Application Case: In a certain automobile manufacturing plant, the NI SCXI – 1163R is used in the production line to control the robotic arm. By switching the power supply of the robotic arm, the movement and operation of the robotic arm are accurately controlled, which improves the production efficiency and quality of the automobile. The module has been running stably in this production line for a long time, reducing the failure rate of the equipment and the maintenance cost.

Comparison with Similar Products

Compared with similar products, the NI SCXI – 1163R has the following advantages: it has a higher maximum switching voltage and current, which can meet the needs of more high – power equipment switching; it has better compatibility with software, which can provide users with more programming options and reduce development costs; its optical isolation performance is better, which can adapt to more complex electromagnetic environments and improve the stability of the system.

Selection Suggestions

  • Compatibility: Make sure that the NI SCXI – 1163R is compatible with your existing equipment and software. For example, if you are using National Instruments’ data acquisition equipment and programming software, this module can be well integrated.
  • Installation Environment: Consider the installation space and environmental conditions. The dimensions of the NI SCXI – 1163R are 6.8 x 8.0 x 1.2 in, and it requires a suitable installation space. At the same time, pay attention to the temperature and humidity of the installation environment. The recommended operating temperature range is 0 to 50 °C1.
  • Budget: The price of the NI SCXI – 1163R is relatively high, but considering its high reliability, easy integration, and other advantages, it has a high cost – performance ratio in some applications. Users can choose according to their actual budget and needs.

Precautions

  • Safety Specifications: Do not try to switch loads over 240 v or 200 ma to avoid damage to the relays1. When installing and using, make sure to cut off the power supply to prevent electric shock.
  • Maintenance Suggestions: Regularly check the connection of the module to ensure that the connection is firm. Clean the module regularly to prevent dust and dirt from affecting its performance. If there is a problem, contact the professional maintenance personnel in time.

 