LYD000A

¥4,259.00

argument
Voltage: 24V DC
Current: 60 mA
Output frequency: 50Hz
Range: 110-221 (automatic voltage regulation)
Drive current: adjustable from 0.0A/ phase to 3.0A/ phase
Control accuracy: ± 0.5 ° C (displayed as ± 1 ° C)
specification
Overall dimensions:
253232mm (one size)
25x136x92mm (another specification)
Color: Standard
Weight:
0.12 kg (one size)
0.3kg (another size)

Category:

Description

argument
Voltage: 24V DC
Current: 60 mA
Output frequency: 50Hz
Range: 110-221 (automatic voltage regulation)
Drive current: adjustable from 0.0A/ phase to 3.0A/ phase
Control accuracy: ± 0.5 ° C (displayed as ± 1 ° C)
specification
Overall dimensions:
253232mm (one size)
25x136x92mm (another specification)
Color: Standard
Weight:
0.12 kg (one size)
0.3kg (another size)
series
Lide series
trait
Redundant output: There are usually multiple output channels, which are redundant, that is, they provide the same output signal during normal operation to prevent a single point of failure from affecting the system.
Fault detection and switching: It can detect the fault of the output channel and automatically switch to the standby channel to maintain the normal operation of the system.
Communication interface: With Ethernet, RS-232, RS-485 and other communication interfaces, in order to communicate with other control systems or monitoring equipment to achieve remote monitoring and fault diagnosis.
Programming and configuration: It is necessary to program and configure according to the specific application to determine the redundant configuration and switching conditions of the output channel.
Durability: Industrial-grade durability, stable operation in harsh industrial environments, resistance to vibration, humidity and temperature changes and other conditions.
Photoelectric isolation signal input/output
Error protection: including overheat protection, overcurrent, low voltage protection
effect
Industrial automation: In industrial automation systems, used to ensure redundant control of critical equipment and actuators to prevent the impact of a single point of failure on the production process.
Power distribution: In power distribution systems, used to ensure redundancy of power supply to prevent power outages and system failures.
Manufacturing: In manufacturing, it is used to ensure the redundant operation of critical equipment on the production line to reduce downtime.
Traffic system: Used to ensure the redundant operation of traffic signals and rail signals to maintain traffic safety.
Telecommunications equipment: In telecommunications equipment, used to ensure the redundancy of communication equipment and signal transmission to prevent communication interruptions.
Building automation: Used to ensure the redundant operation of control and monitoring equipment in building automation systems to improve the availability of building equipment.