HONEYWELL FC-SAI-1620M

¥6,023.00

Parameters and specifications:
Number of channels: 16 analog inputs.
Input signal: 0(4)-20 mA.
Power Supply: 24 VDC.
Safety level: SIL3, in line with IEC61508 standard.
Features: Has isolated analog 0V shared by all 16 channels.
Size and weight:
Dimensions: 10.2 x 7.6 x 1.2 inches (approximately 259.1 x 193 x 30.5 mm).
Weight: 1.2 pounds (about 0.54 kg); It is also reported to be 0.2kg.
Category:

Description

Parameters and specifications:
Number of channels: 16 analog inputs.
Input signal: 0(4)-20 mA.
Power Supply: 24 VDC.
Safety level: SIL3, in line with IEC61508 standard.
Features: Has isolated analog 0V shared by all 16 channels.
Size and weight:
Dimensions: 10.2 x 7.6 x 1.2 inches (approximately 259.1 x 193 x 30.5 mm).
Weight: 1.2 pounds (about 0.54 kg); It is also reported to be 0.2kg.
Series:
HONEYWELL FC-SAI series analog input modules.

Features:
High performance and reliability: It can operate for a long time in harsh industrial environments, and has features such as dust, water and shock resistance, suitable for application scenarios requiring high reliability and stability.
Fast response: With fast signal processing capability and response time, it can monitor and control various industrial processes and machines in real time.
Flexibility and scalability: It can be customized and expanded according to different application requirements, and can be used with various sensors and actuators to achieve a variety of control and monitoring functions.
User-friendly: With a friendly user interface and easy-to-use tools, it is easy for users to configure, manage and maintain.
Remote monitoring and control: Support remote access and control to reduce the frequency and cost of on-site maintenance.
High security: Supports a variety of security protocols and technologies, such as encrypted communication, access control, fault detection, etc., to ensure the safety and stability of factory operation.

Functions:
Safety monitoring: Receive analog input signals from various safety sensors and equipment, such as temperature, pressure, liquid level, etc., to detect the operating status of plant equipment in real time.
Safety protection: When abnormal conditions are detected, a signal is sent to the control system to trigger safety protection measures, such as shutdown or emergency stop of the process.
Fault diagnosis: Help diagnose system or equipment faults by monitoring changes in analog input signals.
Data logging: A data logging function that records and stores monitored signal changes is important for accident investigation, operational analysis, and compliance reporting.

Reviews

There are no reviews yet.

Be the first to review “HONEYWELL FC-SAI-1620M”

Your email address will not be published. Required fields are marked *

Post comment