Description
Parameters and specifications
Rated current: 40 A
Rated voltage: DC 700 V
Version: 3
Firmware: Standard firmware
Size and weight
Size: The overall size is about 132mm105mm52mm
Weight: 800g net
series
Brand: REXROTH
trait
Protection grade: IP30 protection grade of the shell, reinforced by wavy aluminum shell
Installation method: 35mm DIN guide rail is supported
Working environment: The working temperature range is -10-70℃ (-40~+85℃ wide temperature is optional), the relative humidity is less than 90% (no condensation), and the storage temperature range is -40~ 80℃
Test certification: Iec61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5 (Surge), IEC61000-4-6 (CS), IEC61000-4-8 (MS) and IEC61000-4 have been adopted -11 (Dips) and other test certification
Communication capability: with logic independent dual bus electrical interface, can realize the backup of electrical interface or single device access dual redundant bus system; Support Profibus DP bus standard, communication rate up to 1.5MBit/s to 12MBit/s
effect
Automation applications: DKCXX.3-040-7 is commonly used in automation and motion control applications, such as robots, CNC machine tools, automated production lines, etc
Precise control: It can help achieve precise speed control and position control to meet high-precision industrial automation requirements
Network redundancy: In the application of optical fiber network, it has the function of double optical port to realize the redundancy of double fiber ring network. When an optical fiber fails, the system can rebuild the network link within 10ms to ensure the normal communication of the system
Reviews