TRICONEX 3401 ¥4,512.00 Parameters and Specifications: Operating Voltage: 24VDC Operating Temperature: -40℃ to +70℃ Communication Interface: RS485 Output Type: Digital Signal Product Dimensions: 120mm x 80mm x 30mm Weight: 0.5kg1 Series: Not specifically mentioned as a series, but rather a model or controller type.
TRICONEX 3301 ¥5,412.00 Parameters and specifications: I/O type: digital input, digital output, analog input, analog output. Number of channels: 8, but there are also 32 channel versions, such as the TRICONEX DI3301 digital input module. Redundancy: 1+1 redundancy. Isolation voltage: 1500 Vrms. Operating voltage: Not directly mentioned, but standard voltage that may be applicable to Triconex systems. Operating temperature: -40°C to +70°C (for TRICONEX 3301 redundant I/O modules) or -40°C to +85 °C (for TRICONEX DI3301 digital input modules). Communication interface: Supports the communication interface of the Triconex system, as well as communication with other control systems, PLCS and SCADA systems.
TRICONEX 3664 ¥5,214.00 Parameters and specifications: Type: I/O expansion module Number of channels: 8 or 16 Analog input: 4-20 mA, 0-10 V Analog output: 4-20 mA, 0-10 V Discrete input/output: relay contacts Redundancy: 1oo2, 2oo3 Certification: SIL 3, IEC 61508
TRICONEX 4201 ¥5,262.00 Parameters and specifications: Input voltage: 24V DC. Operating temperature range: There are two statements, one is -40°C to 70°C, and the other is 0 to 85 °C. Maximum number of inputs: 64 digital inputs and 16 analog inputs. Maximum output: 64 digital outputs and 8 analog outputs. Communication protocols such as Modbus and DNP3 are supported. Program capacity: 16MB. Number of serial ports: 4 Fiber Ethernet port: 100 Mbps.
TRICONEX 3351 ¥3,260.00 Parameters and Specifications: Input Voltage: 24V DC1 Input Current: 100 ma1 Output Voltage: 24V DC1 Output Current: 500 ma1 Operating Temperature Range: -40℃ to 85℃1 Storage Temperature Range: -40℃ to 85℃1
TRICONEX 3504E ¥6,235.00 Parameters and specifications: Input voltage: 100-240VAC. Output voltage: 24VDC (fixed value, non-adjustable). Maximum output current: 10A. Operating temperature range: According to different search results, there are two statements, respectively -20 ° C to 60 ° C and -40 ° C to 70 ° C. Sampling period: 100ms. Output: 3 relays or 2 relays and continuous/logical outputs for external setpoints.
TRICONEX 3008 ¥6,235.00 Parameters and specifications: Input voltage range: 10.5-30 volts (RMS) Output voltage range: 0-10 volts (RMS) Output current: up to 24 amps Frequency: Max. 2500 Hz Accuracy: ±1% Size and weight: Size: 150mm x 100mm x 50mm
TRICONEX 3481 ¥6,235.00 Parameters and Specifications: Model: TRICONEX 3481 Brand: Triconex (acquired by Honeywell and integrated into its safety product portfolio) Power: 250W Current: 24 mA Voltage: 240 Volts Frequency: 1000 Hz Temperature Range: Approximately 100°C
TRICONEX 3481 ¥5,236.00 Parameters and Specifications Model: TRICONEX 3481 Brand: Triconex (acquired by Honeywell and integrated into its safety product portfolio) Origin: USA Color: Typically black Power: 250W Current: 24mA Voltage: 240V Frequency: 1000Hz Temperature Range: Approx. 100°C
TRICONEX 3704E ¥5,026.00 Parameters Input Signals: Supports 16 digital input and 16 digital output signals12. Operating Voltage Range: 24VDC to 48VDC12. Communication Protocol: Supports Modbus communication protocol12. Operating Modes: Programmable12. Specifications Dimensions: 266mm x 205mm x 120mm2. Weight: Not specifically mentioned, but likely lightweight for its size and application. Operating Temperature Range: -20°C to 60°C2. Operating Humidity Range: 5% to 95% (non-condensing)2. Safety Ratings: IEC 61508 SIL 3, IEC 61511 SIF 3, EN2.
TRICONEX 3511 ¥5,260.00 Parameters and specifications Parameter specifications: Module type: analog input module Input signal: 4-20 mA, 20-320 mA current loop Output signal: 6 or 2 simple type Output accuracy: ±0.1% Output range: 0-10 V, 0-20 mA, 0-5 V Isolation: Input/output isolation, isolation between channels Fault diagnosis: Module fault or channel fault Certification: CE, UL, CSA
TRICONEX 4351B ¥5,260.00 Parameters and Specifications Model: 4351B Brand: TRICONEX (now part of Schneider Electric) Type: Safety System Controller Certifications: SIL 3 capable, TÜV and other safety certifications Dimensions and Weight Exact Dimensions and Weight: Not provided in the general information. Please refer to the official TRICONEX or Schneider Electric documentation for detailed measurements.