Showing 121–132 of 347 results

PXIE-8861

¥5,132.00

Model Number: NI PXIE-8861.
Processor: Based on high-performance Intel Xeon E3-1515 processor.
I/O Interfaces:
Two Thunderbolt 3.0 ports.
Two Display ports.
Two USB 3.0 and four USB 4 ports.
Two Ethernet ports (one with 1588 timing support).
Serial and GPIB ports.
System Support: Runs Windows 10 applications and interfaces with external PCIe-based instruments.

Dimensions and Weight:

Dimensions:
Width: 229mm
Height: 151mm
Depth: 53mm.
Weight: Not specifically mentioned, but it is typically lightweight and compact for easy integration into PXI systems.

PXI-6115

¥3,206.00
NI PXI-6115
Product Parameters:
Manufacturer: National Instruments (NI)
Type: PXI Module
Form Factor: PXI
Bus Type: PXI Express
Specifications:
Analog Output Channels: 4 channels
Output Type: Voltage
Resolution: 16 bits
Update Rate: Up to 250 kS/s per channel
Accuracy: ±(0.005% of reading + 0.0015% of range + 50 μV)
Output Range: ±10 V
Output Noise: 20 μVrms (0 to 10 V range)

PXIE-8861

¥4,685.00
NI PXIe-8861 is a high-performance embedded controller based on the PCIe Extensions for Instrumentation (PXI) bus standard. The following is a detailed explanation of the parameters, specifications, dimensions, weight, series, features and functions of NI PXIe-8861:
argument
Processor: Based on the high-performance Intel Xeon E3-1515 processor.
I/O ports: Includes two Thunderbolt 3.0 ports, two Display ports, two USB 3.0 and four USB 4 ports, two Ethernet ports (one of which is 1588 enabled), serial and GPIB ports.
System support: Run Windows 10 applications to interact with external PCI-based instruments.
specification
Size: Specific size information about the NI PXIe-8861 is not explicitly mentioned in the search results.
Weight: Approximately 8kg.

PXIE-6739

¥5,641.00
The NI PXIe-6739 is a high density analog output module designed for applications such as high density excitation-response testing and open loop simulation. The following is a detailed explanation of the parameters, specifications, dimensions, weight, series, features and functions of NI PXIe-6739:
argument
Number of channels: 16 bits, 64 channels
Sampling rate: 1 MS/s
Voltage output: Supports static and software timing voltage output applications
Digital I/O lines: Contains 20 digital I/O lines
specification
Size: 10.6CM×9.3CM×2.3CM
Weight: Specific weight information is not explicitly mentioned in the search results provided.

PXIE-8523

¥5,268.00
The NI PXIe-8523 is a module designed for automotive Ethernet interfaces. The following is a detailed explanation of the module’s parameters, specifications, dimensions, weight, series, features and functions:
argument
Interface type: 100/1000BASE-T1 Unshielded Twisted Pair (UTP) automotive Ethernet interface
Number of ports: 4 ports
Application: Application development with NI-XNET driver
specification
Maximum number of connections: Up to four independent endpoints or up to two network terminal Access Points (taps)
Timestamp feature: Has an onboard hardware timestamp that can be used as up to four independent 802.1AS master or slave stations
Front panel function: The front panel is equipped with leds for monitoring network connectivity and activity
Size and weight
Size: Specific size information is not explicitly mentioned in the search results provided.
Weight: Specific weight information is not explicitly mentioned in the search results provided.

SCXI-1104C

¥5,362.00
NI SCXI-1104C is a high-performance, multi-channel analog signal acquisition module, the specific parameters, specifications, dimensions, weight, series, features and functions are as follows:
Parameters and specifications
Number of channels: Usually 16 differential input channels, supporting a variety of signal types.
Resolution: A 24-bit analog-to-digital converter (ADC) is provided to ensure highly accurate data acquisition.
Sampling rate: The maximum sampling rate is 100 kS/s, but the specific rate may vary according to application requirements.
Input voltage range: ±10 V, suitable for a variety of common signal types and voltage standards.
Input impedance: 1 MΩ || 5 pF to ensure stable signal transmission.
Connection mode: SCXI terminal board is used to connect various sensors and signal sources.
Size and weight: 3.3 x 22.9 x 14.0 cm, 0.36 kg.
Size and weight
Dimensions: 3.3 x 22.9 x 14.0 cm.
Weight: 0.36kg.

SCXI-1349

¥4,515.00
The NI SCXI-1349 is a high-performance data acquisition device designed specifically for the NI SCXI platform. The following are the parameters, specifications, dimensions, weight, series, features and functions of NI SCXI-1349:
Parameters and specifications
Voltage: 24V
Current: 100-400A
Analog input: 32 channels
Analog output: 4 channels
Digital I/O: 8 channels
Maximum sampling rate: 1ms/s
Resolution: 16 bits
Communication interface: USB
Size and weight
Dimensions: 9.5 “x 5.5” x 2.0 “(241.3mm x 139.7mm x 50.8mm)
Weight: 1.5 pounds (about 0.68kg)

SCXI-1125

¥6,520.00
The following information is available about the parameters, specifications, dimensions, weight, series, features and functions of the NI SCXI-1125:
Parameters and specifications:
Type of measurement: Differential or single-ended thermocouple input
Number of channels: 8 differential or 16 single-ended
Input type: Thermocouple (J, K, R, S, T, N, E, B)
Accuracy: ±0.5°C(J, K, T, E), ±1.0°C(R, S, N, B)
Isolation voltage: 1000 Vrms
Cold end compensation circuit: built-in
Size and weight:
Dimensions: 3.78cm x 12.19cm x 20.32cm
Weight: 454 grams

PXI-6683

¥6,588.00
NI PXI-6683 is a PXI synchronization module, the following are its parameters, specifications, dimensions, weight, series, features and functions:
Parameters and specifications:
Type: PXI Synchronization module.
Function: Synchronize multiple PXI modules to operate multiple PXI enclosures in master and slave configurations, or synchronize enclosures with external instruments.
Clock Type: On-board temperature compensated crystal Oscillator (TCXO).
Clock accuracy: Not specifically mentioned, but long-term stability can be achieved with GPS, IEEE 1588, and IRIGB taming.
Trigger capability: The ability to route clock signals and triggers within the PXI chassis or between multiple chassis with low skew.
Size and weight:
Dimensions: 6.3 x 3.9 inches.
Weight: 7.2 ounces.
Series: A family of PXI modules in NI’s PXI platform devices.

PXI-6052E

¥5,444.00
The NI PXI-6052E is a versatile data acquisition (DAQ) device, and the following are its parameters, specifications, dimensions, weight, series, features and functions:
Parameters and specifications:
Resolution: 16 bits.
Maximum sampling rate: 1.25 MS/s per channel.
Analog input: 16 single-ended input or 8 differential input.
Analog output: 2 channels.
Numeric I/O: 24 lines.
Counter/timer: 2.
Input voltage range: ±10v.
Input impedance: 1mohm | 25pf.
Output voltage range: ±10v.
Output impedance: 50 ohms.
Digital I/O voltage level: TTL/CMOS.
Size and weight:

PXI-6052E

¥6,555.00
The NI PXI-6052E is a versatile data acquisition (DAQ) device.
Product Description: The device has 16 analog inputs and 2 analog outputs, as well as 8 digital I/O (DIO) lines. In addition, it comes with two 24-bit counters/timers that support analog and digital triggers, as well as 15 analog input ranges.
Product parameters: With a sampling rate of up to 333 kS/s and a 16-bit resolution, this performance can be achieved on 16 single-ended analog inputs. Depending on the hard drive type, the device can transfer data to disk at a rate of up to 333 kS/s. The voltage is 24V, the current is 100-400A, and the weight is 2KG.

PXI-6052E

¥5,412.00
The National Instruments PXI-6052E is a high-performance PXI bus digital I/O module. Here is a detailed explanation of the product:
Product description
The PXI-6052E is a 32-channel PXI digital I/O module designed for test and measurement applications that require high-speed, high-precision digital I/O. It offers flexible configuration options and excellent performance, making it ideal for automated test systems, embedded system development, and digital signal processing in general.
argument
Number of channels: 32
I/O Type: Digital I/O
Maximum sampling rate: Depends on the specific configuration and mode
Input voltage range: Usually compatible with logic levels (e.g. 0V to 5V or 0V to 3.3V)
Interface type: PXI bus
specification
Size: Standard PXI module size (usually 100mm x 98mm)
Power requirements: PXI bus power supply
Operating ambient temperature: usually between 0°C and 55°C