PXIE-8861 ¥5,132.00 Model Number: NI PXIE-8861. Processor: Based on high-performance Intel Xeon E3-1515 processor. I/O Interfaces: Two Thunderbolt 3.0 ports. Two Display ports. Two USB 3.0 and four USB 4 ports. Two Ethernet ports (one with 1588 timing support). Serial and GPIB ports. System Support: Runs Windows 10 applications and interfaces with external PCIe-based instruments. Dimensions and Weight: Dimensions: Width: 229mm Height: 151mm Depth: 53mm. Weight: Not specifically mentioned, but it is typically lightweight and compact for easy integration into PXI systems.
PXI-6115 ¥3,206.00 NI PXI-6115 Product Parameters: Manufacturer: National Instruments (NI) Type: PXI Module Form Factor: PXI Bus Type: PXI Express Specifications: Analog Output Channels: 4 channels Output Type: Voltage Resolution: 16 bits Update Rate: Up to 250 kS/s per channel Accuracy: ±(0.005% of reading + 0.0015% of range + 50 μV) Output Range: ±10 V Output Noise: 20 μVrms (0 to 10 V range)
PXIE-8861 ¥4,685.00 NI PXIe-8861 is a high-performance embedded controller based on the PCIe Extensions for Instrumentation (PXI) bus standard. The following is a detailed explanation of the parameters, specifications, dimensions, weight, series, features and functions of NI PXIe-8861: argument Processor: Based on the high-performance Intel Xeon E3-1515 processor. I/O ports: Includes two Thunderbolt 3.0 ports, two Display ports, two USB 3.0 and four USB 4 ports, two Ethernet ports (one of which is 1588 enabled), serial and GPIB ports. System support: Run Windows 10 applications to interact with external PCI-based instruments. specification Size: Specific size information about the NI PXIe-8861 is not explicitly mentioned in the search results. Weight: Approximately 8kg.
PXIE-6739 ¥5,641.00 The NI PXIe-6739 is a high density analog output module designed for applications such as high density excitation-response testing and open loop simulation. The following is a detailed explanation of the parameters, specifications, dimensions, weight, series, features and functions of NI PXIe-6739: argument Number of channels: 16 bits, 64 channels Sampling rate: 1 MS/s Voltage output: Supports static and software timing voltage output applications Digital I/O lines: Contains 20 digital I/O lines specification Size: 10.6CM×9.3CM×2.3CM Weight: Specific weight information is not explicitly mentioned in the search results provided.
PXIE-8523 ¥5,268.00 The NI PXIe-8523 is a module designed for automotive Ethernet interfaces. The following is a detailed explanation of the module’s parameters, specifications, dimensions, weight, series, features and functions: argument Interface type: 100/1000BASE-T1 Unshielded Twisted Pair (UTP) automotive Ethernet interface Number of ports: 4 ports Application: Application development with NI-XNET driver specification Maximum number of connections: Up to four independent endpoints or up to two network terminal Access Points (taps) Timestamp feature: Has an onboard hardware timestamp that can be used as up to four independent 802.1AS master or slave stations Front panel function: The front panel is equipped with leds for monitoring network connectivity and activity Size and weight Size: Specific size information is not explicitly mentioned in the search results provided. Weight: Specific weight information is not explicitly mentioned in the search results provided.
SCXI-1104C ¥5,362.00 NI SCXI-1104C is a high-performance, multi-channel analog signal acquisition module, the specific parameters, specifications, dimensions, weight, series, features and functions are as follows: Parameters and specifications Number of channels: Usually 16 differential input channels, supporting a variety of signal types. Resolution: A 24-bit analog-to-digital converter (ADC) is provided to ensure highly accurate data acquisition. Sampling rate: The maximum sampling rate is 100 kS/s, but the specific rate may vary according to application requirements. Input voltage range: ±10 V, suitable for a variety of common signal types and voltage standards. Input impedance: 1 MΩ || 5 pF to ensure stable signal transmission. Connection mode: SCXI terminal board is used to connect various sensors and signal sources. Size and weight: 3.3 x 22.9 x 14.0 cm, 0.36 kg. Size and weight Dimensions: 3.3 x 22.9 x 14.0 cm. Weight: 0.36kg.
SCXI-1349 ¥4,515.00 The NI SCXI-1349 is a high-performance data acquisition device designed specifically for the NI SCXI platform. The following are the parameters, specifications, dimensions, weight, series, features and functions of NI SCXI-1349: Parameters and specifications Voltage: 24V Current: 100-400A Analog input: 32 channels Analog output: 4 channels Digital I/O: 8 channels Maximum sampling rate: 1ms/s Resolution: 16 bits Communication interface: USB Size and weight Dimensions: 9.5 “x 5.5” x 2.0 “(241.3mm x 139.7mm x 50.8mm) Weight: 1.5 pounds (about 0.68kg)
SCXI-1125 ¥6,520.00 The following information is available about the parameters, specifications, dimensions, weight, series, features and functions of the NI SCXI-1125: Parameters and specifications: Type of measurement: Differential or single-ended thermocouple input Number of channels: 8 differential or 16 single-ended Input type: Thermocouple (J, K, R, S, T, N, E, B) Accuracy: ±0.5°C(J, K, T, E), ±1.0°C(R, S, N, B) Isolation voltage: 1000 Vrms Cold end compensation circuit: built-in Size and weight: Dimensions: 3.78cm x 12.19cm x 20.32cm Weight: 454 grams
PXI-6683 ¥6,588.00 NI PXI-6683 is a PXI synchronization module, the following are its parameters, specifications, dimensions, weight, series, features and functions: Parameters and specifications: Type: PXI Synchronization module. Function: Synchronize multiple PXI modules to operate multiple PXI enclosures in master and slave configurations, or synchronize enclosures with external instruments. Clock Type: On-board temperature compensated crystal Oscillator (TCXO). Clock accuracy: Not specifically mentioned, but long-term stability can be achieved with GPS, IEEE 1588, and IRIGB taming. Trigger capability: The ability to route clock signals and triggers within the PXI chassis or between multiple chassis with low skew. Size and weight: Dimensions: 6.3 x 3.9 inches. Weight: 7.2 ounces. Series: A family of PXI modules in NI’s PXI platform devices.
PXI-6052E ¥5,444.00 The NI PXI-6052E is a versatile data acquisition (DAQ) device, and the following are its parameters, specifications, dimensions, weight, series, features and functions: Parameters and specifications: Resolution: 16 bits. Maximum sampling rate: 1.25 MS/s per channel. Analog input: 16 single-ended input or 8 differential input. Analog output: 2 channels. Numeric I/O: 24 lines. Counter/timer: 2. Input voltage range: ±10v. Input impedance: 1mohm | 25pf. Output voltage range: ±10v. Output impedance: 50 ohms. Digital I/O voltage level: TTL/CMOS. Size and weight:
PXI-6052E ¥6,555.00 The NI PXI-6052E is a versatile data acquisition (DAQ) device. Product Description: The device has 16 analog inputs and 2 analog outputs, as well as 8 digital I/O (DIO) lines. In addition, it comes with two 24-bit counters/timers that support analog and digital triggers, as well as 15 analog input ranges. Product parameters: With a sampling rate of up to 333 kS/s and a 16-bit resolution, this performance can be achieved on 16 single-ended analog inputs. Depending on the hard drive type, the device can transfer data to disk at a rate of up to 333 kS/s. The voltage is 24V, the current is 100-400A, and the weight is 2KG.
PXI-6052E ¥5,412.00 The National Instruments PXI-6052E is a high-performance PXI bus digital I/O module. Here is a detailed explanation of the product: Product description The PXI-6052E is a 32-channel PXI digital I/O module designed for test and measurement applications that require high-speed, high-precision digital I/O. It offers flexible configuration options and excellent performance, making it ideal for automated test systems, embedded system development, and digital signal processing in general. argument Number of channels: 32 I/O Type: Digital I/O Maximum sampling rate: Depends on the specific configuration and mode Input voltage range: Usually compatible with logic levels (e.g. 0V to 5V or 0V to 3.3V) Interface type: PXI bus specification Size: Standard PXI module size (usually 100mm x 98mm) Power requirements: PXI bus power supply Operating ambient temperature: usually between 0°C and 55°C