Showing 493–504 of 688 results
¥ 4,658.00
Type: Transient Data Interface Module.
Manufacturer: Bently Nevada.
Series: 3500 series.
Input signal: -10 Vdc to +10 Vdc.
Power consumption: 7.7 Watts.
Shaft and sensor power supplies: -24 Vdc.
Function: Interface to software compatible with 3500 monitoring systems, including System 1 status monitoring and diagnostic software and 3500 system configuration software.
Communication: Combine 3500/20 rack interface modules (RIM capabilities) with communication processors (such as TDXnet) to collect data.
Function: Continuously collect steady-state and transient dynamic (waveform) data and transmit this data to the host software over an Ethernet link.
¥ 5,036.00
Parameters and Specifications
Measurement Range : 0-5 g
Resolution : 0.01 g
Sampling Frequency : 10 kHz
Output : BNC interface, analog signal output
Power Supply : Through connection to acquisition system or external battery
Operating Temperature Range : -18°C to +60°C
Storage Temperature Range : -40°C to +85°C
Dimensions and Weight
Dimensions : 97mm x 45mm x 24mm (or 229mm x 102mm x 44mm, depending on the specific model or variant)1 2
Weight : 1.5 kg (for the 229mm x 102mm x 44mm variant)2
¥ 5,222.00
Parameters and Specifications :
Model : 3500/42-01-00
Type : 3500 Monitoring System Relay Module
Number of Channels : 1 (or as specified)
Voltage Rating : As specified by the module’s configuration
Current Rating : As specified by the module’s configuration
Operating Temperature : -40°C to 85°C
Storage Temperature : -55°C to 125°C
¥ 4,520.00
Parameters and Specifications :
Input Voltage (AC) : 100-240 VAC, 50/60 Hz2
Output Voltage (DC) : 24 VDC1
Input Current : 2 A1
Output Current : 5.5 A1
Size : 3.35 x 9.5 x 10.25 inches (85 x 242 x 260 mm)1
Weight : 4.0 pounds (1.8 kilograms)1
Operating Temperature : 0°C to 60°C1
DC Output Stability : ±1%1
Overload Protection : 120% rated current, automatic protection1
Short-circuit Protection : Automatic protection1
Input/Output Isolation Resistance : 500 VDC, greater than 10 MΩ1
¥ 4,659.00
Parameters and Specifications :
Type : Reciprocating Pulse/Speed Monitor
Channels : 4-Channel Monitor
Input : Accepts input from seismic sensors
Functions : Pulse Acceleration, Reciprocating Acceleration, Reciprocating Speed, and Low-Frequency Reciprocating Speed1 2
Measurement : Adjusts signals to obtain various vibration measurements1
Comparison : Compares adjusted signals with user-programmable alarms1
¥ 6,021.00
Parameters and Specifications :
Input Voltage : 24 VDC1
Operating Temperature : -40°C to +85°C1
Humidity Range : 5% to 95% RH1
Vibration Input Range : 4.0 g pk to 50 g pk1
Vibration Frequency Range : 0 Hz to 10 kHz1
Output : 4-20 mA current loop1
¥ 4,162.00
Parameters and Specifications :
Model : 3500/22M
Brand : Bently Nevada
Type : Vibration Monitor
Channels : 2 Channels (Dual Channel Monitor)
Measurement Range : Depends on sensor used and configuration
Accuracy : Specified by Bently Nevada
Dimensions and Weight :
Dimensions : Exact dimensions may vary slightly. Please refer to the official Bently Nevada documentation for detailed measurements.
Weight : The weight is not typically specified for individual monitors. However, you can estimate the weight by checking the packaging or shipping information.
¥ 4,215.00
Parameters and Specifications :
Model/Part Number : 3500/42-01-00
Brand : BENTLY
Type : Vibration Monitoring and Protection Module
Range : 42MM (for displacement, speed, and acceleration measurements)
System : 3500 Monitoring System TSI (Turbine Supervisory Instrumentation)1 2
Dimensions :
Exact dimensions are not provided, but typically modules within the 3500 framework follow standard rack-mount dimensions. The 3500 framework itself has two sizes: full-size (19-inch EIA) and mini-size (12-inch)3 .
¥ 4,625.00
Parameters and Specifications :
Type : 3500/22M
Brand : Bently Nevada
Measurement : Vibration
Sensor Type : Velocity Transducer
Frequency Range : Typically used for low-to-medium frequency vibration monitoring1
Sensitivity : Specified by the manufacturer, typically expressed in mV/mm/s or mV/in/s
Operating Temperature Range : Specified by the manufacturer, typically a wide range for industrial applications
¥ 6,320.00
Parameters and Specifications:
Sensor Inputs: Provides multiple sensor inputs for monitoring various parameters like vibration, speed, temperature, etc.
Signal Processing: Capable of processing and analyzing sensor signals to detect equipment issues or abnormalities.
Alarm Outputs: Includes alarm outputs to trigger notifications or alarms when certain conditions are met.
Communication Interfaces: Supports communication protocols like Modbus or Ethernet for remote monitoring and control.
Power Supply: Accepts standard industrial power supply voltages and frequencies.
Dimensions and Weight:
Dimensions: Exact dimensions are not provided, but it is typically a rack-mountable or panel-mountable unit.
Weight: The exact weight is not specified.
¥ 4,211.00
Parameters and Specifications:
Sensor Inputs: Provides a specific number of sensor inputs (exact number may vary based on configuration).
Sensor Types: Supports various types of sensors, including accelerometers, speed sensors, and proximity sensors.
Signal Processing: Capable of processing and analyzing sensor signals.
Alarm Outputs: Provides alarm outputs for monitoring and notification of abnormal conditions.
Configuration: Configurable via software or hardware settings.
Dimensions and Weight:
Size: Exact dimensions are not provided, but it is typically a rack-mountable or panel-mountable unit.
Weight: The exact weight is not specified.
¥ 4,522.00
Parameters and Specifications:
Inputs: Provides four sensor inputs and four temperature inputs.
Sensor Support: Each sensor input can be configured to support 2-wire and 3-wire accelerometers, speed sensors, or proximity sensors.
Temperature Support: Each temperature input supports E, J, K, and T type thermocouples as well as 2-wire or 3-wire RTD.
Outputs: Offers six relay outputs, four 4-20 mA recorder outputs, and one dedicated buffered output.
Output Configuration: Users can configure the outputs based on OK, Alert, and hazardous conditions of any channel or combination of channels.