Showing 5077–5088 of 6671 results

ABB DSQC539

¥5,360.00

Parameters and Specifications:

  • Data Interface: 9-pin Sub_D socket connector with pin definitions compliant with Profibus DP protocol specifications1.
  • Supported Protocol: Supports Profibus DP bus standard1.
  • Communication Rates: 9.6kBit/s, 19.2 kBit/s, 45.45kBit/s, 93.75kBit/s, 187.5kBit/s, 500kBit/s, 1.5MBit/s, 6MBit/s, and 12MBit/s1.
  • Signal Delay (Electrical Port): ≤11Bit1.
  • Protection: 4000V lightning protection, 1.5A overcurrent protection, and 600W surge protection1.
  • Fiber Interface: Supports multi-mode 850nm, 1310 nm; single-mode 1310 nm, 1550nm wavelengths with transmission distances up to 2Km (multi-mode) and 20Km (single-mode)1.
  • Power: Dual power redundant input, DC(9-36)V, typical DC24V, power consumption less than 4W, with DC1500V voltage isolation and reverse connection protection1.

ABB AI625

¥4,251.00

Parameters and Specifications:

  • Type: Analog Input Module
  • Brand: ABB
  • Model: AI625
  • Control Principle: Other (Specific to Application)
  • Purpose: Automatic Voltage Regulation
  • Measurement Range: 150-210 (Dependent on Application)
  • Accuracy: 0.5%
  • Resolution: 12-bit (For S600 I/O Modules)
  • Input Signal: 4-20 mA (For S600 I/O Modules)

ABB P-HA-RPS-32200000

¥4,522.00

Parameters and Specifications:

  • Rated Voltage: Mainly single-phase 220~240V (small-capacity inverters in household appliances) or three-phase 220V or 380~460V. In China, the rated voltage of low-voltage inverters is mostly three-phase 380V12.
  • Rated Frequency: Generally specified as 50Hz or 60Hz, with 50Hz in China12.
  • Output Voltage: As the output voltage of the inverter varies with the frequency, the rated output voltage can only be specified as the maximum value among the output voltages, which is usually equal to the rated input voltage1.
  • Rated Output Current: The maximum current allowed to be output for a long time, which is the main basis for users to select the inverter1.
  • Rated Output Capacity: Determined by the product of the rated output voltage and the rated output current1.

ABB PPC902AE101 3BHE010751R0101

¥3,650.00

Parameters and Specifications:

  • Model: PPC902AE101 3BHE010751R0101
  • Type: Programmable Logic Controller (PLC) Module1
  • Processor Type: Intel Pentium M2
  • Processor Speed: 1.4 GHz2
  • Memory: 1 GB DDR22
  • Storage Capacity: 80 GB SATA2
  • Communication Interfaces: 6 USB 2.0, 4 Serial Ports, 2 Ethernet Ports, 1 VGA Port2
  • Operating Temperature: 0°C to 50°C2

ABB SC510

¥6,235.00

Parameters and Specifications:

  • Brand: ABB
  • Model: SC510
  • Type: High Voltage Frequency Control Board1
  • Applications: Used in various industrial automation control systems, such as power systems, manufacturing, and pump control2

Dimensions and Weight:

  • Exact Dimensions: Not specified, but generally varies based on the type and application3.
  • Weight: Not specified, but may range from 6.5 to 86kg3.

ABB PFEA112-65

¥6,236.00

Parameters and Specifications:

  • Processor: 16-bit1
  • User Program Memory: 64 KB2
  • Data Memory: 32 KB1
  • Digital Inputs: 161
  • Digital Outputs: 161
  • Analog Inputs: 81
  • Power Supply: 24 V AC/DC2
  • Operating Voltage Range (of Sensor): DC24V (18~36V)2
  • Power (of Sensor): 7.5W2
  • Frequency (of Sensor): 45~65Hz2
  • Tension Unit Quantity (of Sensor): 22
  • Excitation Signal Current (of Sensor): 0.5 Ams, 330Hz2

ABB UFC762AE101

¥5,620.00

Parameters and Specifications:

  • Control Type: PID, Fuzzy, Adaptive Control1
  • Input Signals: Analog (0-10V, 4-20mA), Digital (ON/OFF)1
  • Output Signals: Analog (0-10V, 4-20mA), Digital (ON/OFF)1
  • Control Accuracy: ±0.1%FS1
  • Communication Interfaces: RS485, Modbus, Profibus1
  • Operating Temperature: -10℃ to +55℃4
  • Power Supply Voltage: AC220V/DC24V1

ABB PHARPS32200000

¥4,526.00

Parameters and Specifications:

  • Input Voltage: 90-264VAC
  • Input Current: 11.5A
  • Output Voltage: 24VDC
  • Output Current: 32A
  • Power: 768W
  • Operating Temperature: -20℃ to +70℃
  • Dimensions: 270mm x 144mm x 60mm
  • Weight: 5kg

ABB CI858

¥6,200.00

Parameters and Specifications:

  • Brand: ABB
  • Series: CI858 Series
  • Input Voltage: 24VDC1
  • Current: 100 mA1
  • Communication Protocol: PROFIBUS DP12
  • Baud Rate: Up to 12 Mbit/s2
  • Operating Temperature: -40°C to +85°C1
  • Storage Temperature: -40°C to +85°C1
  • Dimensions: (May vary depending on the model)
    • Width: 59mm (2.3 inches)3
    • Height: 185mm (7.3 inches)3
    • Depth: 127.5mm (5.0 inches)3
  • Weight: 0.3 kg (for CI858K01 3BSE018135R1 model)1

ABB DSAI130A

¥6,032.00

Parameters and Specifications:

  • Model/Part Number: DSAI130A
  • Manufacturer: ABB
  • Series: Not specifically mentioned (But it’s an ABB product)
  • Power Supply: 24 VDC12
  • Power Consumption: < 5W1, < 4W2
  • Operating Temperature:
    • Range: -40°C to +85°C1, -20 to +60°C3
    • Wide Range Option: -40°C to +85°C2
  • Relative Humidity: 0% to 95% (Non-condensing)1, ≤90% (No condensation)2
  • Vibration: 0.05 g RMS (20 Hz to 2,000 Hz)1
  • Shock: 5 g (Half-sine wave, 11 ms duration)1

ABB REM610

¥6,235.00

Parameters and Specifications:

  • Model/Part Number: REM610
  • Manufacturer: ABB
  • Brand: ABB
  • Application Range: Standard medium and large asynchronous motors12345
  • Motor Capacity: 500 kW to 2 MW2
  • Protection Functions: Motor thermal overload, motor start monitoring, rotor stall, phase overcurrent, undercurrent, negative sequence protection, zero sequence current, and breaker failure protection1
  • Communication Interfaces: RS-485 or fiber optic interface, supporting protocols like MODBUS RTU/ASCII, IEC60870-5-103, DNP3.0, and SPA1
  • Fault Recording: Complete fault status recording with four analog input channels and up to eight user-selectable digital channels1
  • Self-diagnosis: Monitors the relay’s condition and issues warning signals before failure1

ABB 3BSE002348R1/SB511

¥5,235.00

Parameters and Specifications:

  • Model/Part Number: 3BSE002348R1/SB511
  • Type: Backup Power Supply Module
  • System Compatibility: ABB DCS (Distributed Control System)
  • Voltage Range: Not Specified
  • Output Power: Not Specified
  • Operating Temperature: 1-40℃
  • Environmental Humidity: 10-90%RH1

Dimensions and Weight:

  • Size/Dimensions: Not Specified (Exact measurements may vary)
  • Weight: 2-7kg1